0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MDS-350AD701 AA

MDS-350AD701 AA

  • 厂商:

    DELTA(台达)

  • 封装:

    -

  • 描述:

    Switching Power Supplies 350W Medical ATX Form Factor Power Supply

  • 数据手册
  • 价格&库存
MDS-350AD701 AA 数据手册
TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply MDS-350AD701 Highlights & Features • ATX 12 V standard function & form factor • IEC60601-1 3.1 ed.(Medical) & IEC 62368-1 (ITE) • • • • approvals Suitable for type BF patient access applications Built-in active PFC Maximum output power of 350 watts Compliant with IEC 60601-1-2 4th Ed. requirements Safety Standards CB Certified for worldwide use Model Number: MDS-350AD701 AA Unit Weight: 1.2 Kg (2.6 lb) Dimensions (L x W x H): 194 x 100 x 40.5 mm 7.64 x 3.94 x 1.59 inch General Description The MDS-350AD701 series of internal ATX power supplies comes with universal AC input from 90 Vac to 264 Vac. Other features include low leakage, availability of risk management report, and electric shock protection compliant with 2 x MOPP requirements. The MDS series is certified for EMC standards according to EN/BS EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment; and, EN/BS EN 55032 for Industrial Technology Equipment (ITE) radio-frequency equipment. The MDS-350AD701 series comes with both Medical and ITE safety approvals, including UL/CE (5000 m) and CB certification and are fully compliant with RoHS Directive for environmental protection. Model Information Table 1 (For Maximum Output Power Limits, see “Output Power” requirements on Page 2) Output Voltage Minimum Load (A) Normal Load (A) Maximum Load (A) Load Regulation Ripple & Noise +3.3 V 0.5 8 16 +/- 5% 50 mVpp +5 V 0.5 9 18 +/- 5% 50 mVpp +5 Vsb 0.0 1.25 2.5 +/- 5% 150 mVpp +12 V1 1.0 8 16 +/- 5% 120 mVpp +12 V2 1.0 8 16 +/- 5% 120 mVpp -12 V 0.0 0.25 0.5 +/- 10% 120 mVpp -5 V 0.0 0.1 0.2 +/- 10% 50 mVpp Model Numbering MDS 350 A Delta Medical Power Supply Max Wattage in the Product Series. Family Code 1 A~ Z D Product Type D: Enclosure 701 Output Voltage 701: +3.3 V, +5 V, +5 Vsb, +12 V1, +12 V2, -12 V, -5 V All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) A Revision Code A Revision code TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 90-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Input Current (max) 6A Input Surge Voltage (max) 300 Vac for 100 ms Full load Efficiency (typ.) 82% @ 115 Vac/60 Hz 85% @ 230 Vac/50 Hz Inrush Current (max) No damage, cold start Leakage Current (max) 0.1 mA @ NC, 0.3 mA @ SFC1) Output-PE (protective earth) Leakage current for BF application (max) 0.1 mA @ NC, 0.5 mA @ SFC Power Factor (min) 0.90 @ 115 V/50 Hz, 230 V/50 Hz, full load 1) NC: normal condition, SFC: single fault condition Output Ratings / Characteristics Nominal Output Voltage (V rated) +12 V1, +12 V2, +5 V, +3.3 V, +5 Vsb, -5 V, -12 V Output Voltage Tolerance See Table 1 on page 1 Output Power Maximum combined output power of +3.3 V & +5 V outputs, shall not exceed 130 W. Maximum combined output power of +12 V1, +12 V2, +3.3 V & +5 V outputs shall not exceed 331 W Maximum combined output power from all the outputs shall not exceed 350 W ±0.5% Line Regulation (max) Load Regulation (max) Ripple & Noise (typ.) See Table 1 Start-up Time (max) (Remote on_off @ TTL Low, then AC applied) 1000 ms @ 115 Vac Hold-up Time (min) 17 ms @ 115 Vac / 60 Hz Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 10% @ 50-100% load1) Rise time (max) 20 ms Remote On_Off/INHIBIT TTL Active Low: Output Enable TTL Active High: Output Disable Power Good (PG) Signal(See page 9 for details) 1. 2. 1) When the dynamic load is applied to one of the outputs, other loads is at minimum load 2 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) PG changes to TTL High 100-500 milliseconds after all outputs reach their final steady state value. After input AC is removed, PG changes to TTL Low at least 1 millisecond before any output falls out of regulation range. TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Ripple & Noise measurement circuit for each output Mechanical Case Chassis SECC (Steel, Electrogalvanized, Cold Rolled, Coil) Case Cover SECC (Steel, Electrogalvanized, Cold Rolled, Coil) Dimensions (L x W x H) 194 x 100 x 40.5 mm (7.64 x 3.94 x 1.59 inch) Unit Weight (typ.) 1.2 Kg (2.6 pounds) Indicator None Cooling System Forced Cooling Environment Surrounding Air Temperature Operating Storage 0°C to +50°C -40°C to +85°C Operating Humidity 5-95% RH (Non-Condensing) Operating Altitude 5,000 meters (16,400 feet) Shock Test (Non-Operating) 50 G, 11 ms, 3 shocks for each direction Vibration (Operating) 5-500 Hz, 2 Grms, 15 minute for each three axis 3 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Protections (Latch Mode protection requires removal of fault, plus removal and reapplication of input AC voltage, in order to restart the power supply. See page 9 for additional details on the different types of protection.) Overvoltage (max) For +3.3 V output, Maximum voltage < 4.8 V For +5 V output, Maximum voltage < 7 V For +12 V1 & +12 V2 outputs, Maximum voltage < 16V Protection Method: Latch Mode For +5 Vsb output, Maximum voltage < 10 V Protection Method: Latch Mode Over load / Over current (max) For +3.3 V output, Maximum current < 25 A For +5 V output, Maximum current < 25 A For +12 V1/+12 V2 output, Maximum current < 25 A Protection Method: Latch Mode For +5 Vsb output, Maximum current < 5 A Protection Method: Auto-recovery Mode Over Temperature Protection Method: Latch Mode Short Circuit on any output. +3.3 V, +5 V, +12 V1 and +12 V2, Protection Method: Latch Mode +5 Vsb, Protection Method: Auto-recovery Reliability Data MTBF (Minimum) at 115 Vac, 35 °C with 350 W Forced Air Flow 500 K hrs based on Telecordia SR-332 Operating Life (Minimum) at 115 Vac, 25°C with 350 W Forced Air Flow 26,280 hrs Safety Standards / Directives Medical Safety IEC 60601-1 Edition 3.1 (2012), EN60601-1 (2006) + A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14, ANSI/AAMI ES60601-1:2005/(R)2012 ITE Safety IEC 60950-1 (Ed.2,2005) & IEC 62368-1 CB report, CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 UKCA In conformance with Electrical Equipment (Safety) Regulations 2016, and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002) Galvanic Isolation Input to/Output(2XMOPP) 4000 Vac Input to/Ground(1XMOPP) 1500 Vac2) Output to/Ground(1XMOPP) 1500 Vac (Type BF application rated) 2) PSU can support PoE applications with Primary to FG 2500 Vac test. 4 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply EMC EMC / Emissions Harmonic Current Emissions EN/BS EN 55011 & Compliant with EN/BS EN 55032, FCC Title 47:Class B IEC61000-3-2 Meet Class D limit Immunity to Voltage Flicker IEC61000-3-3 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A1)5) Air Discharge: 15 kV Contact Discharge: 8 kV Radiated Field IEC61000-4-3 Level 3 Criteria A1) 80 MHz-1000 MHz, 10 V/m AM modulation IEC60601-1-2 Criteria A1)5) 80 MHz-2700 MHz, 10 V/m AM modulation 385 MHz-5785 MHz, 28 V/m Pulse mode and other modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A1) :2 kV Surge IEC61000-4-5 Level 3 Criteria A1)5) Common Mode3): 2 kV Differential Mode4): 1 kV Conducted IEC61000-4-6 Level 2 Criteria A1)5) 150 kHz-80 MHz, 3 Vrms, 6 Vrms at ISM bands and Amateur radio bands Power Frequency Magnetic Fields IEC61000-4-8 Criteria A1)5) Magnetic field strength 30 A/m Voltage Dips5) IEC60601-1-2 Criteria C2) 30% 500 ms Criteria A1) 100% 10 ms at step: 45 degree Criteria C2) 100% 20 ms Criteria C2) 100% 5000 ms 1) Criteria A: Normal performance within the specification limits 2) Criteria C: Output out of regulation, or shuts down during test. (Need to recycle AC power cord or reset enable signal to normal operation after test) 3) Asymmetrical: Common mode (Line to earth) 4) Symmetrical: Differential mode (Line to line) 5) Compliant with IEC-60601-1-2 4th edition requirements. 5 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Dimensions L x W x H: 194 x 100 x 40.5 mm (7.64 x 3.94 x 1.59 inch) Mechanical drawing Notes • Dimension are in mm. • Built-in cooling fan. Must prevent dust suction into power supply, or use natural convection power supply if any concerns. 6 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply DC Output Cable 7 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Functions Start-up Time The time required for the output voltage to reach 90% of its final steady state value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state value. Hold-up Time Hold-up Time is the time between removal of input AC voltage, and the subsequently falling output to reach 90% of its steady state value. 8 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Dynamic Response Over Temperature Protection The power supply output voltage will remain within ±10% of its steady state value, when subjected to a dynamic load 50 to 100% of its rated current. ■ 50 to 100% Load As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating temperature condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into latch mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. Power Good Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The Power Good signal prevents a computer from attempting to operate on improper voltages and damaging itself by alerting it to improper power supply. The ATX specification defines the PowerGood signal as a +5 volt (V) signal generated in the power supply when it has passed its internal self-tests and the outputs have stabilized. This normally takes between 0.1 and 0.5 seconds after the power supply is switched on. The signal is then sent to the motherboard, where it is received by the processor timer chip that controls the reset line to the processor. When plug in AC power cord, +5 Vsb will start first, then Remote On/Off will be pulled low by computer, +12 V1/+12 V2/+5 V/+3.3 V will power on and Power good signal will pull high after 100ms~500ms. After input AC is removed, Power Good signal changes to TTL Low at least 1 millisecond before any output falls out of regulation range. Graph illustrating the AC input, +5 Vsb, Remote On/Off, +12 V1/12 V2/5/3.3 V, Power good signal Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 4 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. Short Circuit Protection The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied to any of the outputs, the power supply will latch off. Overload & Over current Protections The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated before the output currents reach the limits defined on Page 4. Once the power supply has reached their maximum power limit, the protection will be activated and the power supply will latch off. 9 Remote On_Off/INHIBIT Remote ON_OFF/INHIBIT can be used to enable or disable all outputs, except for the +5 Volt Standby. This signal can be pulled down to a low level of 0.3 volts, or shorted to DC-Return, in order for the main output to be enabled; and, floated (no connection to the signal), or pulled up to a value greater than or equal to 3 volts, in order to disable the main output. When the main output is disabled, the +5 V Standby output will continue to operate. All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07) TECHNICAL DATASHEET Medical ATX Power Supply ATX 12 V 1 U Power Supply Certificate Delta has been certified as meeting the requirement of ISO 13485: 2003 and EN ISO 13485:2012 for the design and manufacture of switching power supply and adaptor for medical device. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC 62368-1. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601. Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. Manufacturer and Authorized Representatives Information Manufacturer Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 10 United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (June 2022, Rev.07)
MDS-350AD701 AA 价格&库存

很抱歉,暂时无法提供与“MDS-350AD701 AA”相匹配的价格&库存,您可以联系我们找货

免费人工找货